Email:[email protected]
No.76 Xinda Rd.,Zhoutie Town, Yixing City, Jiangsu Province, China
Zhongzheng pays special attention to the orders related to the Covid-19, such as boilers for hospitals, face mask production lines and pharmaceutical companies, which are essential weapons to fight against the epidemic.
Learn MoreProduct thermal capacity: 1-20 t/h
Working pressure: 0.7-2 Mpa
Product thermal capacity: 20-75 t/h
Working pressure: 1.25-5.4 MPA
Product thermal capacity: 2 – 20t/h
Working pressure: 1.0-2.5 MPA
Product thermal capacity: 4-35 t/h
Working pressure: 1.0-2.5 MPA
Product thermal capacity: 10 - 75 t/h
Working pressure: 1.25-2.45MPA
Product thermal capacity: 1400-29000 KW
Working pressure: 0.8-1.0 MPA
Email:[email protected]
Note: If you're interested in the product, please submit your requirements and contacts and then we will contact you in two days. We promise that all your informations won't be leaked to anyone.
The dryback boiler reversal chamber has a rear wall that is lined, or jacketed with refractory, which passes combustion gasses from the furnace to multiple tube sheets and reflects burner heat, resulting in exterior radiation losses. The dry back boiler design uses a common rear tube sheet and features convenient fire-side …
View MoreThe dry back design refers to the use of refractory at the back of the boiler in the inversion chamber. The FT Firetube Boilers are specifically designed to minimize the thermal stress on the boiler not only at high pressures, but at low pressures as well. Cutting-edge technologies are used to construct the fire tube …
View MoreReversal chambers located away from the burner are ‘rear reversal chambers‘ whilst those closest to the burner are ‘front reversal chambers‘. Reversal Chamber. Smokebox. The smokebox is the final part of the boiler that the exhaust gas passes through before exiting to the chimney. Smokebox and Chimney. Fire Tube Boiler …
View MoreReversal chamber is the posterior portion of the boiler combustion chamber through which the flue gases travel from the furnace’s first pass to the second pass tubes. And based on the construction of reversal chamber, boilers can be classified into wet-back boilers and dry-back …
View MoreFigure 3.2.1a shows a dry back boiler where the hot gases are reversed by a refractory lined chamber on the outer plating of the boiler. Figure 3.2.1b shows a more efficient method of reversing the hot gases through a wet back boiler configuration. The reversal chamber is contained entirely within the boiler.
View MoreSummary • The firetube boiler is a versatile package suitable for a plethora of applications including heating and process • Typical size range is 100 –2500 HP • Pressures to 350# • Construction follows …
View MoreOct 07, 2016 · There is a reversal chamber for flue gases between 1st & 2nd pass is provided inside the boiler shell.In dryback boiler rear wall is lined with refractory. In dryback boiler reversal chamber has a rear wall that is lined with refractory, which passes combustion gasses from the furnace to multiple tube sheets …
View MoreDry Back Boilers: The reversal chamber in dry back boilers is not completely surrounded by water. The posterior part is exposed to the atmosphere. This leads to the increased radiation losses, as the radiant heat is lost to the atmosphere instead of going to the water as in wet back boilers. Earlier generation boilers used to be dry back.
View MoreSince dry-firing is a covered cause of loss under many boiler and machinery insurance policies, many boiler losses are claimed as dry-firing. Often, we find that is indeed the case, but not all boiler leaks are caused by dry-firing. This white paper will discuss some of the common causes of dry …
View MoreThe double fire-tube boiler with water-cooled reversal chamber and burner penetration has a capacity of 70 t/h and pressures of 0.5 to 40 bar(g). As hot water boilers, the capacity is between 0,5 and 44 MW. The design temperature for the hot water boilers can be up to 200 o C…
View MoreBoilers are available as dry back or wet back (water cooled gas reversal area). The popular Cleaver-Brooks design includes 3 or 4 gas passes with a low furnace location for optimum thermal efficiency (see Figure 1-6), and dry back or wet back arrangement…
View MoreIn the first configuration i.e. dry back boiler configuration, the reversal of hot combustion gases is done via a refractory lined chamber located at the external …
View MoreBWR Fire Tube Boilers feature three pass design and include a tubular construction flue gas reversal chamber. This proven feature, unique to Babcock Wanson, enhances water circulation thereby greatly reducing the risk of internal fouling (sludge accumulation in the bottom of the boiler).
View MoreIf you are interested in our products, or have any questions for us, you can click the button below
Contact UsCopyright © 2020.Boiler All rights reserved.